BT RS232 Troubleshooting
Guide
© Copyright Brainboxes Limited 2005 Page 8 of 16
Question Description
How to upgrade the firmware on
BL-521/730, 819 & 830
Firmware from version 3.01 upwards is field upgradeable:
On the main menu in HyperTerminal select option 6 – Upgrade DFU
Then select option 1 and type “PROCEED” exactly (case sensitive). At this point
you will no longer no able to interact with the menu, it is now in a permanent
state of upgrade.
Now, run the Firmware Upgrade Utility software (DFU Utility) that came with the
CD.
Follow the instructions shown – select the first option “I wish to upgrade the
firmware on my ___”
Next select the COM port to which you have connected your product
Point the upgrade wizard to where you have stored the upgrade file (these all
have extension .dfu)
Follow the onscreen instructions
The firmware should install successfully.
How do I terminate a connection
to a device in HyperTerminal
using a BL-521/730, 819 & 830?
Turn the power off on one device and then the other device will be configurable.
If you do not do this then the menu in HyperTerminal will be unresponsive as
the connection will be still present, also, simply power cycling a device will not
terminate the connection.
Once a device is configurable:
You can set the device as a client or server, so that both devices are either
clients or servers i.e. enter svr=0 to set a device as client or svr=1 to set as
server.
Be careful that another device cannot pair with your devices, if you are using
security mode 2 or higher than this will not be possible unless the other device
is using the same pin number.
If you type delpart this will delete the partner device from the connection and
will allow a new partner device to be entered.
(Please see the manuals for further information)